MSA Blast Resistant Door - Use and Maintenance Manual

MSA Blast Resistant Door - Use and Maintenance Manual

2.266 Lượt nghe
MSA Blast Resistant Door - Use and Maintenance Manual
Blast Resistant Door - Use and Maintenance Manual Application: Military MSA Bunker Type: One single Leaf Moving: Sliding Characteristic: High Impact Resistance - Blast Resistant Design • Development • Manufacturing • Assembling • Validation Shipping • Installation • Qualification by SOPHIA HIGH TECH. Door Size: 7820 mm (length) x 4900 mm (width) x 230 mm (thickness); Door Weight: 16 tons Blast Resistance: blast pressure of 7bar, shock and impact loading verified by FEM Analysis; Corrosion resistance Control: Automatic, Door is actuated by an electric engine 2,2 kW Strandars: - ASTM F 2927 – 12 [Door Systems Subject to Airblast Loadings] - ASTM F2247 [Metal Doors Used in Blast Resistant Applications (Equivalent Static Load Method] - UFC 4-010-01 [Structures to resist the effects of accidental explosions] - DOD Manual 6055.09-M [Ammunition and Explosives Safety Standards] - NATO AASTP-1 [Safety principles for the storage of military ammunition and explosives] - CEI EN 60204-1: 2006 [Safety and Prevention]