CR Scan Accuracy - Capture Range - Marker Test for Raptor X - Raptor - Otter
I made measurement for capture area for Raptor X, Raptor and Otter in each mode, also the testing for optimal marker dot spacing distant for each scanner and finally the accuracy test for long and short distant.
The final result is listed below:
Capture Range: (Optimum Distant)
- Raptor X 32 Lines = 26 x 16 cm
- Raptor X 7 lines and Raptor Original = 10 x 7 cm
- Raptor NIR Large = 30 x 18 cm
- Raptor NIR Medium = 15 x 10 cm
- Raptor NIR Small = 10 x 7 cm
- Otter Small mode = 8 x 6 cm
- Otter Medium mode = 13 x 9 cm
- Otter Large = 55 x 35 cm
Optimal Marker Spacing: (Optimum Distant)
- Raptor 7 lines = 6 cm
- Raptor X 34 lines = 12 cm
- Otter Large mode = 10 cm
ACCURACY TEST:
Fridge height = 1743 mm
RAPTOR X Cross Laser = 1742.925 mm Error = 0.075mm (0.004%)
OTTER Large Mode = 1743.750 mm Error = 0.75mm (0.04%)
Aluminum block = 149.95 mm
RAPTOR X Cross Laser = 149.903 mm Error = 0.047mm (0.031%)
RAPTOR X 7 Lines = 149.902 mm Error = 0.048mm (0.032%)
RAPTOR Original = 149.888 mm Error = 0.062mm (0.041%)
OTTER Small = 149.362 mm Error = 0.588mm (0.392%)
3D print marker download link:
https://skfb.ly/p8VD9
Creality Store Scanner Link (Non-affiliate): https://bit.ly/40ckIRh
Creality Scanner Official Facebook page: https://www.facebook.com/groups/creality3dscanner/
#creality #3dscanning #raptorx #raptor #otter #accuracy #markers